Process Equipment
Flotation Mechanisms, Hydrocyclones (Apex/Vortex), Filter Presses (800–1500 mm) & Pump Skids (CV / ZVZ / CRZ / DC).
Flotation Mechanisms, Hydrocyclones (Apex/Vortex), Filter Presses (800–1500 mm) & Pump Skids (CV / ZVZ / CRZ / DC).
5-5-4 Wet-End Lots in High Chrome (≥650 HB), Rubber, PU & SiC + D075C21 Sleeve & Bearing Assembly.
Marcy Scale (1000 cm³), 3-Cup Hydrocyclone Mass Balance, Lab Batch Filter (60–100 psi) & ASTM E11 Sieves.
E4147A05, D075C21, E4083, TH48-30):
Physical Scale: Recommended front axial clearance: 0.76 mm to 1.50 mm (1 to 2 ISO/IEC 7810 bank cards)
Physical Scale: Sacrificial cutwater wall thickness: 34 mm (45 stacked ISO/IEC 7810 cards)
Physical Scale: Axial clearance calibration against impeller: 0.76 mm (1 ISO/IEC 7810 bank card)
Physical Scale: Secondary chamber radial clearance: 1.52 mm (2 ISO/IEC 7810 bank cards)
Physical Scale: Mirror finish Ra < 0.2 microns; 12.5 mm wall (16 ISO/IEC 7810 bank cards)
Physical Scale: 22 mm vortex-dissipating lip (29 stacked ISO/IEC 7810 bank cards)
Physical Scale: 3.0 mm self-sealing elastomer lip (4 ISO/IEC 7810 bank cards)
Physical Scale: Guaranteed axial interference tolerance: ±0.38 mm (half an ISO/IEC 7810 bank card)
Physical Scale: Tip speed bounded to U2 ≤ 24.5 m/s for zero thermal delamination
Physical Scale: Eliminates 100% of gland seal water when suction head is below 15% of total head H
Physical Scale: Bore stability within ±0.76 mm (1 ISO/IEC 7810 bank card) over 4,000 hours to prevent roping
Physical Scale: Lower lip edge tolerance of 0.76 mm (1 ISO/IEC 7810 card) to shear wall short-circuit flow cleanly
Physical Scale: Internal cone step δ_r ≤ 3.0 mm (< 0.76 mm nominal, 1 ISO/IEC 7810 card) and 3°–5° tapered relief angle for anti-blinding
Physical Scale: Rotor/stator radial ratio Dr/Ds calibrated within 1.5 mm (2 ISO/IEC 7810 bank cards) to sustain Sb ≥ 50 s⁻¹ (Gorain 1997)
Physical Scale: Drop-tight shutoff even over trapped coarse particles up to 15 mm (20 ISO/IEC 7810 cards)
Physical Scale: Twin-sleeve open bore: 100% full-port passage with zero dead pocket
Physical Scale: Sealing rim flatness tolerance: ≤ 0.38 mm (half an ISO/IEC 7810 card) at 16 bar
Physical Scale: Calendered weave thickness: 0.76 mm to 1.15 mm (1 to 1.5 ISO/IEC 7810 cards) for clean cake release
Physical Scale: Mesh 200 opening (75 microns) = 1/10th the thickness of 1 ISO/IEC 7810 bank card (0.76 mm)
Every component dispatched undergoes rigorous dimensional and physical verification in our Durango facility prior to site shipment.
Certified casting integrity backed by chemical spectrometry and ultrasonic non-destructive testing at partner foundries.
Protecting your concentrator plant means knowing our operating limits. We never compromise safety for a blind sale.
Quality Protocol: We do not quote blindly or compromise the safety of your operation. View our technical limits and warranty protocol →